Rinnai Infinity 24 Questions & Answers (page 3 of 4)
66 questions from our users
How do I turn increase temperature on a infinity 24?
When our Infinity 26 was installed by plumber it was able to go to 60 degrees which he did for us. Even though we keep it at 55 degrees for washing dishes etc and 40 degrees for showering. Very rarely...
Read more having to put it to 60 degrees. Would need to talk to Rinnai as to whether your system is able to be increased.Thanks for the question culchey, it will depend on the model of unit you have had installed. The details are on the left hand side of the unit, if you can get the model and serial number of the unit ...
Read moreand contact our Technical Help Desk on 1300 555 545, they will be able to advise if the unit can be adjusted.Why does Lo 79 flash on Rinnai unit?
Thanks for the question Bill, is this unit installed in Australia as we do not have any record of this fault with our units. If it is installed in another country we would recommend contacting your local Rinnai office for advise.
I have a Rinnai Infinity DSC 453 a and doesn't appear to have any power to the control panel. where do I find the power supply for that? Any help would be greatly appreciated. the controller seems to be working does the water I get in the kitchen is hotter than what I have in the shower I just need to warm the shower up.
Regards Ian
Reu-2424W-A About 15 yrs old that works fine when only mains water being used. We have a tank plumbed into the toilets and washing machine. Recently when we have switched over to the tank water and turned on a tap, cold or hot, we get a screaming sound from the Rinnai? This goes away if we switch back over to mains water. Any ideas?
Hi, I have a B24 model and I was wondering if there is a way of increasing the water volume? The water pressure in the shower only is very low. The B24 is just outside the bathroom window.The manual talks about water controller pads. I dont have one in the unit. Is it a remote control or separate unit?
Thank you
Thanks for the question Lisa, we would recommend speaking with our Technical Help Desk to discuss the issue you are having and they may be able to help.
Hi, I have a rennai infinity 24 gas hot water heater, approx 16 yrs old. over the last 2 months the temperature of the hot water has dropped. We no longer need to turn the cold water tap on when showering. Any solutions please?
Thanks for the question Melissa, it is difficult to diagnose the issue without inspection. It may be that the unit requires a service if this hasn't been completed or it may indicate the unit is comi...
Read moreng to the end of its life. We would recommend a service call to confirm what the issue is.We have an Infinity 24 - yesterday, there was water disruption for around 6 hours and this morning I have no hot water. I turned off the power and pulled the plug out for more than 5min, when I plugged it back in and powered it on, hot water came back on put very low pressure to a point that I can't shower. Please advise if I need to make a service call.
Control panel for Rinnai 24 keeps dropping to 12 degrees from the set 50 degrees and water is not consistently hot. Any help?
Thanks for the question WJB, if the control panel is showing 12 it sounds like an error code rather than the temperature. Error 12 usually indicates a Flame Failure/low gas flow. We would recommend ...
Read morechecking that the gas is turned on to the unit, that gas bottles are not empty if you are running on L.P.G. and no obstruction to the Flue outlet. Otherwise you may need to book a service call to identify the issue. Our service and technical teams are available on 1300 555 545 to assist futher.Hi, I was wondering if you should turn it off during the day for power / energy saving or if that won’t make a big difference. Does it use a lot of power ? We have recent moved into a property which has one installed and we love it!
Thanks for the question Scottscott, we're glad to hear you are enjoying your hot water unit. There is no need to turn off the power to the Infinity unit as the unit draws a very small amount of elect...
Read morericity while not in use and even when it is running, the electricity usage is minimal. We recommend always leaving the power on the unit as depending on your location, you will be disabling the frost protection mode on the unit if the power is not switched on.We have an Infinity VT24 unit that is constantly going. Have turned off and waited etc but no change, there is no electronic separate control unit just the box on the wall.
Ta Paul
Thanks for the question pdpc56, this will require a technician to attend, the units should switch off as soon as the hot tap is turned off. Our service team can be reached on 1300 555 545 or you can ...
Read morebook via our website https://www.rinnai.com.au/support-resources/online-service-booking/Hi
We have a Renai 24 and have had it for about 15 years.
It services the whole house for whole water and has 3 controllers.
Just in the last couple of days it has started to act intermittently.
Sometimes its ok and other times there is no water e.g. the hot tap doesn't run.
I have tried turning the power off and then on again and it did start to work again but only for a short while.
What do you suggest as a coarse of action?
Thanks for the question Fred, there could be a number of things that could be causing the issues you have described. The first thing we would suggest is to clean the filter in the unit as a build up ...
Read moreof debris in this filter can cause the unit to fault. Cleaning the shower heads can also make a difference to the flow rate in the unit and can fix the issue. We have a free technical help desk that can help with some fault finding and can arrange for a service call if required if this doesn't help. They are available until 5.30pm week days on 1300 555 545It seems to me that cutting in and out during different times of the day or night is a common problem with Rinnai instant tank-less systems. We have had our Rinnai 24 for a couple of years and it does exactly that. In/Out sometimes during the day. When it's out - completely doesn't work what ever you do (I have been recommended to turn Power switch to it for about 1min, then Turn it On and try it again).
Our question to Rinnai is has this issue been addressed in new models and have you got a solution to it?
Thanks for the question El 2017. Generally if the unit has been installed and sized correctly for the water and gas flow there should be no issue with cutting out. There does need to be a good flow ...
Read morerate through the unit for it to work effectively. if the tap is not turned on enough the unit may cut out. turning the tap on more or using a water controller can resolve this issue. Controllers mean you are setting the temperature you want at the tap so the unit is only having to heat to this temperature and no cold water needs to be mixed. This means the amount of flow rate through the hot water system is increased too.Hi to the service department,
I have Rinnai 24. The unit stop delivering hot water and water start liking from the unit.
Any suggestions.
IS THERE VAFILTER TO CLEAN INSIDE?
Regards,
Bob
Thanks for the question Bob, it is hard to diagnose without inspecting the unit but unless one of the pipes to the unit has developed a leak, the most common issue would be a leaking heat exchanger. ...
Read moreWe would recommend calling our service department on 1300 555 545 to book a service.We have just purchased a house that has a rinnai 24. In the bathroom it has options to "bath fill" although the water does not automatically stop. Have I misunderstood this function. Is there a manual available?
Hi Erin we have the deluxe bathroom controller and the bath fill setting when the amount of litres selected is reached the water flow stops until the function is switched off then water flows again. ...
Read more The manual is available on the rinnai website http://www.rinnai.com.au/hot-water/continuous-flow-hot-water/infinity/16/ . Download selection area and click on (the operation and installation manual) each of the controller types are descried thereI have a infinity 24 and for the last 3 days the water doesn't flow on turning on. I close and open and then it flows. It otherwise get hot as normal?
Good Morning,
Thank you for your enquiry. We will need further information before we can answer your question. Can you please contact our 1stcare Customer Service Team on 1300 555 545 and choose opti...
We have just moved into a house with a Rinnai 24 hot water system. It takes approx 10 litres of water to run until it gets warm/hot in any taps of the house. Accordingly, the water bill is extremely high and is such a waste. What could the problem be? Would appreciate input.
Denise -
I have a Rinnai B24 and we have an all day power outage coming up. Is there any way to manually light pilot to get hot water? Phil
usually no power no hot water unless you are clever and can hook up a battery back up at the unit.
Is there a copy of instructions for how to light a pilot light for a Rinnai Infinity 24 gas hot water heater? I have one where the power went off and it seems to have knocked out the pilot and the instructions have faded away.
Hi Mike C. Try unplugging your unit from the wall at the power point, waiting about 5 mins then plug back in and turn on a hot water tap. This will re set the unit and usually fixes the problem.
Thanks. Unfortunately, the unit was old and apparently the power going off caused the electric board to burn out and had to be replaced with newer gas heater. Fortunate for us really because the gas p...
Read morelumber found a leak in the supply line and fixed that at the same time.My 12 year old infinity 24 suddenly now has fluctuating shower water temperature. Drops from 36 degrees at the shower head to 30/31 every 1 - 2 minutes or so and back up again. Called out a plumber who says it might be a thermostat or the impeller but obsolete model so no parts available. Someone suggested to him to look at installing a control panel. Don't know at what cost but its not sensible to spend money on an old unit I believe. Any idea on sourcing parts?
Sorry. I cant help you eith this.
Being 12 years old the unit may not be lasting too many years longer, anyway. Maybe more economical to just buy a new one. I'm just going on cost. With expensive parts (especially a control panel) and...
Read more expensive plumbers' call out fee and their charge by the hr. It wont be worth it in the end.our infinity 24 goes hot and then cold getting worse its 13 years old, should I have a service or just replace?
If it were me I'd get it serviced first ( but making sure the plumber/ service engineer knew the issues currently experienced).... then, if no improvement get it replaced.
Thanks for the question Jim, it's possible that the fluctuation you are experiencing could be from a build up in the filters and a general service may resolve this issue without replacement. You may ...
Read morealso find calcium build up in the shower heads that restrict the flow of water from the unit can cause this issue as well. Our technical team can talk you through cleaning the filters to see if this makes a difference to the flow, they are available on 1300 555 545 Monday to Friday from 8.00am to 5.30pm.DEAD SEt!!!! I HAD THE SAME PROBLEM AND FOR US IT ENDED up being a spider made a nest in the gas regulator (even inside the wire mesh grill bit) apparently its common for spiders or mud wasp to lay ne...
Read morests in there.... i just found this out 1 hr ago so hopefully that helps THE REGULATOR ON YOUR ACTUAL GAS TANK its worth a shot...... a gas fitter with a million years EXP told us go check it out and reply to me if it worked #yourwelcomeRinnaiGet an answer from our members and Rinnai representatives