Honda EU30is Questions & Answers
19 questions from our users
My2019 eu30i keeps going to overload I ran a cig inverter welder from it at low amps and I was told this could have caused damage to the inverter ? I have replaced the spark plug and rectifier in the hope this would fix the problem but it didnt I am not sure what to do next .
I have a new Honda EU30IS generator. Page 33 of the owners manual shows circuit protection reset push buttons.....my unit does not have these. What happens if I overload the generator ? I am located in Victoria Australia.
Hi, I’ve recently bought a brand new EU30IS and have just changed the oil, not It will start and run for a short time then cut off.
Also, the key jammed on once and flattened the battery, will the battery charge when the genny is running?
Cheers, Steve
Hi Steve,
Ours is not a key start it’s a pull cord so I have no battery issues sorry I can’t be of more help. You should take it back to where you bought it from whilst it’s under warranty. That’s wha...
Read moret we did shortly after purchase and then just get it serviced regularly, still going since 2005. Cheers
I want to buy an ultra quiet 3kva unit. Pls explain the eu30i vers eu30is etc. also the images look very different. Some is 35kg - others twice that?
In our Honda eu30is when starts out put current is not working, any help?
Would having the generator switch on so i can use the remote start flatten the battery?
I just changed the air filter, and the oil, and the generator ran fine. On the second start up, there is a fair amount of smoke coming out of the exhaust, and a very rough idle. Any idea what the issue could be?
It's a year and a half old unit. Cheers.
The first time it happened. To me, I was in shock. The problem was bad fuel. From then I always ran on BP ULTIMATE. MORE RECENTLY I HEARD THAT ULTIMATE made the engine run hotter & on air cooled motor...
Read mores it could be an issue. Probably would run a good quality 95. Generally I found the Honda were over sensitive to such issues.Why does my generator switch off by itself? I pu new plug, air filter, clean fuel whats the problem?
How long can I run the gen at once ?
It depends on the load but I found 8-10 hours thrashing the thing with high loads
Well I only have an ac in the RV that is on so that might be half load.
i need a reliable generator to run my whole van as its my only home i am disabled so need one no heaver than 30 kilos so i can move it as i move around alot ive been told to buy a honda eu30i but cant find weight can u help me also honda has a eu30i handy which would b better for my use n disabilities and can u help me i need to know the weight of the uniots
The eu30is has a dry weight of 60kg 13kg for fuel and 1kg oil brings the grand total to 74kgs! Try for the eu20i less power more reliable and cheaper and also weighs in at about 25kgs full of fluids also it's quieter
I have a EU30iu and thought it would do the job at 12.5 amp max, but my compressor which has a 7.5amp, motor won't start with this generator. I want it to work but it won't. Is there a way I can get it to fire the belt drive compressor, obsiviously the start draw is too much. If not would the EU30is with the 196cc motor do any better?
Terry, very late to the party sorry, the Motor sounds like an old one, most motors draw 6 to 10 times full load current on start up. So, at 7.5 amps Full load current, that's potentially 60 amps draw...
Read more (at 8 times FLC), so no, it will not start it. I suggest a newer motor, low current cap start/run, or a bigger generator.Engine on eu30i, will oneu30i will only run with choke on?
Col
Dissemble carbon and clean with carry intake cleaner replace all gaskets and you should be in business
Sorry disassemble carby
Hi Matt,
I had the same problem recently and had 3 goes at it before I succeeded.
You have to completely disassemble the carby and need a compressor to blow it out. THe main jet iinside the tube in the centre will
...
Hi [name removed] can you parallel a eu20.i with a eu30i?
cheers Barry
Hi Barry, My name's Sarah and I work in the Marketing department here at Honda Power Equipment. Honda does not recommend parallels with units of different output wattage. Generators with different out...
Read moreputs will not have the same inverter, meaning that they will not communicate with each other, it may also result in damage to one of the generators, and/or risk to the operator if one overloads. We tend to recommend that you only parallel units of the same wattage.Hi there what volume of oil does the engine require at service?
Hi Greg,
My name's Sarah and I work in the Marketing department here at Honda Power Equipment.
You can locate this information if the EU30is Owners manual. Link:http://www.hondampe.com.au/docs/own...
What are the physical dimensions please?
Hi Peter,
Dylan from Honda Power Equipment head office here. ...
Read more Dimensions: L: 655 W: 455 H: 555 Weight: 59kg, and it has a 13-litre fuel tank. Hope that helps! You can find out more here: http://powerequipment.honda.com.au/Generators Cheers, DylanGet an answer from our members