54 questions from our users

Sen

Senasked

Avenger AV25N (Natural Gas, White)

Why this model not available in Victoria?



2 answers
jb
jb

Sen, I believe Vic have tougher rules on unflued gas heaters maybe you can only buy to replace an existing unflued heater, but new installs i think require a flued heater. If its the Avenger 25 Plus you are looking at then its unflued and its still available in NSW. I think unflued with high emissions like the avenger should be banned nationally due to the hazard of the gaseous smell the LPG model it emits back into the house. It gets an emissions rating 3.5 stars out of 6.0, so I guess thats about 58% good and 42% bad for you. I had one in NSW and sold it and put in split aircon due to the smell and lack of assistance from Rinnai. The laws in NSW are loose so I guess Rinnai sell more in NSW BUT take my advice steer clear of unflued heaters, the smell is a health risk, its the same reason schools have replaced all their unflued heaters, JB

Rinnai
Rinnai A.Rinnai

Thanks for the question Sen. In Victoria in 2009 there were changes to the Gas Safety Regulations which state a person cannot install any flueless heater as a new installation in residential premises this included not being able to install a new bayonet connection for a flueless heater. You can replace an existing flueless space heater provided the heater meets certain requirements. They are:

* The heater being replaced, and its replacement, operates on Liquefied Petroleum Gas (LPG);
*The emission of oxides of nitrogen from the new heater does not exceed 2.5 ng/J; and,
*The carbon monoxide/carbon dioxide ratio of the new heater does not exceed 0.002.

The Avenger heaters are designed with Oxygen depletion sensors so if the oxygen level in the room drops below a pre-set limit, the device cuts the gas supply to the heater. It is important to follow the manufacturers instructions for minimum ventilation for any unflued heater.



Jane

Janeasked

Avenger AV25SN (Natural, Silver)

Hi,

Bought a 2nd hand Rinnai 25 Convector Heater. Didn't realise the heater was NG and I have LPG. Is there anyway to convert the system so I can use the heater?

1 answer
Rinnai
Rinnai A.Rinnai

Hi Jane, thanks for the question. In most cases you can convert our heaters from NG to LPG but it will depend on the specific model and serial number of the unit. This information can be found on a date plate on the unit and our technical help desk can confirm if the heater you have can be converted. They can be reached on 1300 555 545 option 3.

If the heater can be converted you will need to order the kit through a plumbing supply company (our website can show you the nearest company in your area) and have the kit installed by a licensed gas fitter.



Cuddles

Cuddlesasked

Avenger AV25N (Natural Gas, White)

Have cleaned both rear filters but filter light still flashing. How do you clean the front filter where air leaves the appliance? This appears dirty.

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for the question Cuddles, has the heater been serviced recently? We do recommend servicing of any gas appliance every 2 years as there are areas of the heater that are not accessible without a dismantling the heater. The filters do restrict the majority of dust etc, there are materials that still pass through the filter and deposit in the internal area of the heater.

hayleymachida

hayleymachidaasked

Avenger AV25SN (Natural, Silver)

Hi, i have a Rinnai Avenger 25 and when i turn it on, it ignites and runs nice for 60 seconds then the fan speeds up, then it shuts off. Then it flashes 13.
I've read the manual but can seem to find the problem.
Any ideas?
Thanks

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for the question Hayleymachida. Our heaters are designed to try to self diagnose the issue with the unit. In this case the error code is listed as Thermocouple high cut out or Convection fan over revolution. Both of these errors will require a service call for the heater to identify and diagnose what is causing this cut out. Our service team can be reached on 1300 555 545 from 8.00am- 5.30pm EST Monday to Friday, or you can book online at http://www.rinnai.com.au/support-resources/online-service-booking/

kathleen

kathleenasked

Avenger AV25SL (LPG, Silver)

My Heater turns on starts then after about 60 seconds flashes number 18 in the room box and cuts out. Any ideas?

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for the question Kathleen. Error code 18 could be an issue with the temperature sensor on the heater and it is shutting down as a safety precaution. A service call will be required to investigate and resolve this issue. Our service team is available Monday to Friday from 8.00am-5.30pm or you can book online at http://www.rinnai.com.au/support-resources/online-service-booking/

gary

garyasked

Avenger AV25L (LPG, White)

Hi, my gas rinnai heater still has a smell each time i use it. It's been 8 months and been used for a total of 10 hrs.
Is there anything that can been done?
PS: do have tons of ventilation, but this still smells.

2 answers
Rinnai
Rinnai A.Rinnai

Thanks for the question Gary. There are a few things we can run through with you with our Rinnai technical team, It's a free service available Monday to Friday 8.00am-5.30pm EST. They can be reached on 1300 555 545 and troubleshoot over the phone on a solution for you.

Barry Smith
Barry Smith

We bought ours last year and it had a smell at first, but not now, we use ours for about 5 hours every night.

Tasha

Tashaasked

Avenger AV25SN (Natural, Silver)

Who stockists the conversion kits gas to lpg? I live near Ellenbrook and work in the Joondalup area Perth.

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for the question Tasha. If you go to the Rinnai Australia website you can enter your postcode and all the local stockist will be listed. If the store doesn't have the kit in stock they can order it in for you. The website is www.rinnai.com.au

jimmy

jimmyasked

Avenger AV25L (LPG, White)

Can you get a conversion kit to change from lpg to natural gas and where do i purchase one from?

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for your question Jimmy, yes you can buy a conversion kit for the Avenger 25 heater. You can order these kits from any good plumbing supply shop. If you visit the Rinnai website you can enter your postcode and it will give you the closest retailers in your area. Alternatively you can call 1300 555 545 and speak to our sales team who can advise you further

kni6508

kni6508asked

Avenger AV25L (LPG, White)

I have recently purchased an LPG Avenger 25. When it starts up it usually shows that the room temperature is about 20 degrees when its obviously about 14 degrees or less. It is in an open area with no other heat source. The room temperature indicator never seems to vary much, it usually shows either 19 or 20 degrees. Everything still works ok but its annoying because the set temperature then has to be manually adjusted higher than the room temperature for the heater to still heat & the fan to still operate on high. Is it just a faulty thermostat that needs replacing?

2 answers
Steve
Steve

I have the same problem

DOUG R.
DOUG R.

Same problem with my Capella 18Plus. Is this an inherent fault?

happy shopper

happy shopperasked

Avenger AV25N (Natural Gas, White)

Hi I have two avenger 25 and am super happy. I could however do with a longer hose. Where is the best place to purchase just the hose from? - I have googled but nothing seems to come up for the hose alone. Thanks

1 answer
Shazj
Shazj

Hi, did you get an answer because I'm looking to do the same?thanks Sharon

Hose problem

Hose problemasked

Avenger AV25L (LPG, White)

Hi, I had my heater on "GAS ECON AUTO OFF" mode. The "AUTO OFF" was flashing. What does that mean? I changed it to" GAS ECON AUTO OFF MODE" and it worked fine.
Also it's rather confusing trying to work out which mode to use.
How do I decide which one to use, there doesn't seem to be any outlines in the book as to which mode to use.
Regards
Grant

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for your question. We recommend calling our friendly technical staff who will be able to explain the different functions of the heater. They can be reached on 1300 555 545.

marks1807

marks1807asked

Avenger AV25L (LPG, White)

I have a rinnai avenger 25 rce671tr that has just had its jets changed from natural to lpg but now it runs for 60 seconds and then shows fault 18. Anyone know why?

1 answer
Rinnai
Rinnai A.Rinnai

Thanks for your question Marks1807. Error 18 normally indicates a lack of gas to the unit. If it has been recently been converted we would recommend having the gas plumber who performed the conversion, return to check gas supply to the unit and there are no blocked points. We have a technical help line on 1300 555 545 who can also advise on areas they can check when on site.

Pang Gunawan

Pang Gunawanasked

Avenger AV25N (Natural Gas, White)

Just about to use the rinnai avenger (have been using it for 5 years
just suddenly it says " lock "
PLease adviise to unlock?
Thanks
Pang

1 answer
Rinnai
Rinnai A.Rinnai

Thank you for your enquiry.

From your description it sounds like the lock function on the heater has been activated.

To deactivate the Lock function press both the Up and Down buttons simultaneously for 3 seconds. The Lock indicator will go out to show that the Lock function is no longer active. The Lock function can be deactivated at any time in this manner.

Our customer contact centre an be contacted on 1300 555 545 if you require further assistance.

Ang105

Ang105asked

Avenger AV25L (LPG, White)

Does the fan on the Rinnai 25 Avenger use a lot of electricity. Can I turn it off somehow(fan only) Is there a low option as it seems to be full on all the time and I have to switch it off. There is probably a simple explanation sorry

3 answers
spookyluke
spookyluke

Hi
The fan stays on as that is what draws the cold air thru the system then pushes out the hot. Minimal power used and won't work without.
Lower your thermostat and turn economy mode on, then once room is at temperature it will tick away quietly maintaining temperature.

Ang105
Ang105

Thank you so much for your quick response much appreciated. You have made a non technical girl very happy

JC_1972
JC_1972

Yep, turn the temperature to the room temp (or lower) or put in Economy, that does the trick. My Electricity bill was normal after 2 months of having my new heater. However I just opened my 1st gas bill and nearly had heart failure - $181 more than this period last year! My old Rinnai died and was under-rated (in size) for the newer house so I thought getting a bigger unit would make it need to work less, plus it is rated relatively well, seems I was wrong. I'm off to go turn my heater down now...

Page 3 of 3
See all Rinnai Avenger 25 / 25Plus questions

Get an answer from our members and Rinnai representatives

ieatwords.com.au has affiliate partnerships. These do not influence our content moderation policies in any way, though ieatwords.com.au may earn commissions for products/services purchased via affiliate links.