107 questions from our users

Hayley P.

Hayley P.asked

Archer Gas Log Fires

I have a Model FS100 installed 2/6/07 this unit has been working well up to a couple of weeks ago when the front burning would not light so we were using the rear burning and then last night it was switched off in the normal manner and today would not light at all . fan running on slow and the front trying to light by flashing on front of the panel but no glow power switched off and left awaiting advice.
Regards
Craig



1 answer
Aurora
Aurora A.Aurora

Hello, Hayley best to call Aurora directly they will be able to assist you contact numbers are 1300 388 953 or (03)9795 8895 or E-Mail [email protected] best regards Albert .....

Ray W

Ray Wasked

Archer Gas Log Fires

Hi I have an archer gas log fire is700 built 4/5/2016, the convection fan spins very slow but no fan lights are illuminated when both burners are on

1 answer
Aurora
Aurora A.Aurora

Hello, Ray, it sounds like your thermistor may need adjusting or it is not signaling back to control board cant be 100% sure without more information best to call Aurora they are the manufacturer of the Archer gas log fire ph numbers are 1300 388 953 or (03)9795 8895 or E-Mail [email protected] thank you ...

Graeme Kershaw

Graeme Kershawasked

Archer Gas 100 Series

Change Fahrenheit to Celsius on the remote



1 answer
Aurora
Aurora A.Aurora

Hello Graeme on the remote you just need to hold the up and down buttons at the same time and this will change it from Fahrenheit to celsius or give us a phone call to guide you through the procedure, numbers are 1300 388 953 or (03)9795 8895 or E-Mail [email protected] thank you .....

rob

robasked

Archer Gas Log Fires

Hi, I have an older free standing Archer model (possibly FS100). Last winter we had renovations to build a new deck in the area behind the wall where the heater is located and we changed the fluing from a straight through the wall arrangement to a through the ceiling arrangement. The ceilings are quite high (no cavity) and the flue is close to the 5.1m limit.

We also had a new water pump installed in the humidifier unit at about the same time.

The heater seemed to operate effectively for a couple of months including the pump as we routinely heard the hiss as water was pumped to the evaporation plate. However, one evening when turning the heater off I found a significant pool of water on the floor. Unfortunately we can't recall whether we heard the hiss of water from the humidifier that evening as after a while these types of noises become part of the background and while you might notice them happening you rarely notice that they aren't happening.



Is it likely that the problem has been caused by a failure of the humidifier pump or could there also be complications with the flue? There is one clear difference with our flue installation - due to the lack of a ceiling cavity there isn't a "bend" of the flue in the ceiling cavity using two 45 degree joins as per the installation instructions.

We live on the south coast of NSW and there is no authorised rep in the area, nor will any gas heater company look at the heater. Keen to see if we can get this fixed as it has been a very good heater and replacement cost is significant. If you know of anyone in the Nowra area that can assist I would be grateful.

No answers
PaulV

PaulVasked

Archer Gas 100 Series

Hi Guys we've had our FSP100 for some time and happy with it...this season the fan speed seems as its stuck on one speed...whereas last season I could "hear" it kick into the high speed mode, any suggestions?

1 answer
Aurora
Aurora A.Aurora

Hello, Paul, it sounds like your relay is stuck in your control module or one-off your motor run capacitors needs replacing, we rally need to know the age of your unit and model type, even better if you give us a phone call we would be more than happy to assist you in diagnosing your heater ph numbers are 1300 388 953 or (03)9795-8895 or E-Mail [email protected] thank you best regards Albert ............

barry t.

barry t.asked

Archer Gas 100 Series

The fan only runs on high speed even though the heater is set on low, the front burner has been running all day but fan will not vary speed, runs flat out.
Can you help? Barry

1 answer
Aurora
Aurora A.Aurora

Hello you may just need a thermistor which is the device that controls the speed of your convection fan if you give us a phone call when you are in front of your heater we can better diagnose it for you PH No 1300 388 953 or (03)9795 8895 between 9:00 am and 5:00 pm Mon to Fri hope this is of some help to you best regards from Aurora climate systems. EMAIL questions are best directed to [email protected] Thank you............

Marian N.

Marian N.asked

Archer Gas 100 Series

I bought Archer Gas Log Fire FSP 100 5 years ago,so far everything was fine,but recently the back burner has stopped working the front burner is fine.I tried to reset but nothing changed, what's the cause.Mark.

1 answer
Aurora
Aurora A.Aurora

Hello it sounds like you may just need a coil for your gas valve or if you have a remote you may need to relearn it if you give us a call when you are in front of your heater we can properly diagnose it for you or put you in touch with a tech our phone numbers are 1300 388 953 or (03) 9795 8895 9to5 Mon to Fri best regards from Aurora climate systems

Dave

Daveasked

Archer Gas Log Fires

How to clean convection fan on fs 100 archer heater

1 answer
Aurora
Aurora A.Aurora

depending on the age and model there are several ways to clean the fan the most common is to unplug and unscrew to remove it from the heater then just vacuum out the fan wheel and replace back in heater if you need more help please call Aurora the manufacturer of the Archer gas log fires PH 1300 388 953 or (03) 9795 8895

Andy

Andyasked

Archer Gas Log Fires

Front burner almost went out (small blue flame near the jets only), back burner flame was different (solid orange, no flickering) & strong chemical smell coming from it. Now that it’s cold, the glass is completely cover in thick black soot. Have cleaned glass, logs have not moved & we are not out of gas.

1 answer
Aurora
Aurora A.Aurora

you will need to lower your gas pressure to clean the soot out of your heat exchanger or just run one burner at a time it is probably best to give us a call to explain how to fix this problem our numbers are 1300 388 953 or (03)9795 8895 best regards from Aurora climate systems the manufacturer of the Archer gas log fires.......

Craig

Craigasked

Archer Gas 100 Series

Our unit has a remote and red button which we use all the time. Lately when the front flame is on the fan continiously switches between low and med or med off then med on again. Can you please reccommend a service technician that specializes in Archer log heaters in the Diamond Valley area in Melbourne.

2 answers
Aurora
Aurora A.Aurora

If you call Aurora they will give you a recommended service person for your heater the numbers are 1300 388 953 or (03)9795 8895 look forward to your call best regards from tech support at Aurora Climate systems...........

Craig
Craig

Thanks. Dean Allsop Electrical did a great job to repair the heater.

hastings 8

hastings 8asked

Archer Gas 100 Series

we have a remote but lost instuctions on how to set it please can you advise

1 answer
Aurora
Aurora A.Aurora

Please call Aurora and they will send or E-Mail you the instructions phone numbers are 1300 388 953 or (03)9795-8895 thank you best regards, Albert ......

Rose S.

Rose S.asked

Archer Gas 700 Series

Hi we had our Archer gas heater model IS760 installed yesterday it looks beautiful and heats wonderfully but the noise the fan makes is very loud? One of the reasons we replaced our previous heater was because of the loud fan . Whenwe observed our chosen heater at your showroom the heater was very pleasingly quiet, any ideas as to why it is so loud would love to have this rectified ASAP.

1 answer
Aurora
Aurora A.Aurora

you probably need to adjust the position of your thermistor and check your gas pressure you might be able to change your conv fan to something different or smaller

Serres M.

Serres M.asked

Archer Gas Log Fires

Hi bought an Archer IS900 and esthetically their isn't much of a display flame wise. Is this normal or can flame be adjusted to be more prominent.
Cheers Arthur

2 answers
gunrealty
gunrealty

Most of these types of gas log fire heaters have three types of heat source. They are: flame only, stones, or logs....I have a combination of stones and logs, and in my opinion, it is better to have the flame heat up (to red hot) some logs or stones, rather than rely on the heat from the flame only (think of the old style cast iron kitchen stoves, but in saying that, I'm no scientist).....have a chat with ARCHER - you might still be able to change what they call the "log set".

Aurora
Aurora A.Aurora

need to check gas pressure, burner position and log positions they are adjustable and will have an effect on the way the heater burns and what the flames look like.........

Patricia S

Patricia Sasked

Archer Gas Log Fires

We have a Model FS100 set into the wall. Its approx. 12years old. Not often used.
We tried to start it recently, but to no avail. We switched it on at the wall, then both switches on the front of the unit. The lights come on, but the 'fire' doesn't start. What could we do for this? Do you do service calls? thank You, Patricia

1 answer
Aurora
Aurora A.Aurora

Yes, we can organize a service call please call Aurora on 1300 388 953 or (03)9795 8895 ........

Bill

Billasked

Archer Gas 700 Series

Our Archer gas log fire as of yesterday has the fan running on full all the time even when not in use. The only way to stop it is to switch off at power point. I turned it back on this morning and fan starts up on full blowing out cold air We have never had any trouble b4 this.

2 answers
Aurora
Aurora A.Aurora

i dont know how old your heater is but it sounds like you might need a 40-degree switch or thermistor

Bill
Bill

Thanks for your reply, unfortunately it took a long time(2 months) for you to reply and we had to get someone to have a look at it before then. The fan needed a bit of adjusting. I gather they are excellent heaters but when something goes wrong the supplier doesnt want to know about it.

Cath

Cathasked

Archer Gas Log Fires

Best way to clean the glass front

1 answer
Aurora
Aurora A.Aurora

best way to clean glass is with car cut and polish..........

Breanca B.

Breanca B.asked

Archer Gas Log Fires

How to change from Fahrenheit to Celsius on thermostat?

1 answer
Aurora
Aurora A.Aurora

if you have the current remote you just need to hold the up and down buttons at the same time......

rowan

rowanasked

Archer Gas 300 Series

HI.. My gas log heater remote control keeps playing up so decided to remove the remote control and place back in manual operation.Looking at the manual to place back in manual operation you remove the battery operated receiver unit from the heater which also removes the wiring loom to the red light and reintall the links which were left in the heater in case you wanted to return the heater to manual operation. . After reinstalling the 3 piece links that can only go one way the heater does not work anymore and worse still wont work if I put it back as was..Previously when you turned the 240 v ac power on the unit made a noise like a relay or something like that closing now just a slight hum of the transformer Front panel led, only light up from the batteries in the receiver not from the heater .If the 240ac power is turned off the front panel led per the batteries still shows led power on. Any help please? Regards Greg

2 answers
rowan
rowan

Just adding a bit more info. My mistake looks to be 100 series with electronic control not a 300, We only moved in a couple of months ago and only recently found the instructions to the heater when we realised the remote was not working..Upon inspection at the heater found the receiver with four badly corroded AA batteries.which in turn had damaged the battery contacts.I suspect previous owners had not changed them for years.My thought was after reading the instructions on how to attach the remote control in the first place by removing the three links was to remove the damaged reciver even though it had a toggle switch to bypass the remote and reinstate the three links to put back as exiting before the remote was installed. As stated before that the links provided can only go one way on the pins so are completely puzzled by the end result..In the end cleaned the receiver and contacts up as best I could and placed back in wih new batteries .240v power on with no led power on light on front panl . With batteries in and reciever in remote power led light comes on even if 240v power is off, Heater does not work and are the batteries back feeding the system? Any help appreciated. regards Greg

Aurora
Aurora A.Aurora

the best way to help you is to give you guidance over the phone it is to difficult and there are too many questions to be answered so please call us on 1300 388 953 or(03)9795 8895........

Michael C

Michael Casked

Archer Gas 900 Series

Hi we have changed the flu fan in our log fire nut now it wont start have uou sny ideas whst might br going wrong thanks Michael

2 answers
gunrealty
gunrealty

Sorry, I'm not the guru on these heaters ! Try Aurora in Victoria......

Aurora
Aurora A.Aurora

you need to check your pressure switch lines are fitted correctly or for more advice please call Aurora on 1300 388 953 thank you for your question.............

Geoff R

Geoff Rasked

Archer Gas Log Fires

Further to my last question re sooting up on rear burner probe. Can gas pressure be adjusted without heater running? Says something in the manual about burners being in operation while adjustment is made. Woulnt have thought this would be necessary!

2 answers
Aurora
Aurora A.Aurora

Hello Geoff you can turn the pressure down without the heater running but you won't be able to see the setting on your monometer unless the heater is running if you like you can give us a phone call and we can guide you through the correct procedure when you are in front of your heater our Numbers are 1300 388 953 or (03)9795-8895 between 9:00 am and 5:00 pm Mon to Fri hope this has been of some help best regards from tech support at Aurora climate systems the manufacturer of the Archer gas log fire....

Geoff R
Geoff R

Ive sent you another message. I didnt provide enough detail last time. Im getting a sooty veil of carbon forming on the rear burner( between the igniter and the frame below.) This earths out the igniter and stops it from relighting. After cleaning, away it goes again. Will a decrease in gas pressure solve this issue or is there a mixture adjustment or other mechanical solution that you can recommend. Regards, Geoff